FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource ValueSet/FHIR Server from package nhsd.assets.stu3#1.7.0 (93 ms)

Package nhsd.assets.stu3
Type ValueSet
Id Id
FHIR Version R3
Source https://simplifier.net/resolve?scope=nhsd.assets.stu3@1.7.0&canonical=https://fhir.nhs.uk/STU3/ValueSet/DCH-BloodSpotOutcomeSCDSnCT-1
Url https://fhir.nhs.uk/STU3/ValueSet/DCH-BloodSpotOutcomeSCDSnCT-1
Version 1.0.0
Status draft
Date 2017-12-04T00:00:00+00:00
Name DCH Blood Spot Outcome SCD SnCT
Experimental False
Authority hl7
Description A code from the SNOMED Clinical Terminology UK coding system that describes the outcome of the blood spot screening for sickle cell disease.
Copyright This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement.

Resources that use this resource

No resources found


Resources that this resource uses

CodeSystem
http://snomed.info/sct SNOMED CT (all versions)
http://snomed.info/sct Nutrition Care Process Terminology module
http://snomed.info/sct veri


Source

{
  "resourceType" : "ValueSet",
  "id" : "DCH-BloodSpotOutcomeSCDSnCT-1",
  "url" : "https://fhir.nhs.uk/STU3/ValueSet/DCH-BloodSpotOutcomeSCDSnCT-1",
  "version" : "1.0.0",
  "name" : "DCH Blood Spot Outcome SCD SnCT",
  "status" : "draft",
  "date" : "2017-12-04T00:00:00+00:00",
  "publisher" : "NHS Digital",
  "contact" : [
    {
      "name" : "Interoperability Team",
      "telecom" : [
        {
          "system" : "email",
          "value" : "interoperabilityteam@nhs.net",
          "use" : "work"
        }
      ]
    }
  ],
  "description" : "A code from the SNOMED Clinical Terminology UK coding system that describes the outcome of the blood spot screening for sickle cell disease.",
  "copyright" : "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement.",
  "compose" : {
    "include" : [
      {
        "system" : "http://snomed.info/sct",
        "concept" : [
          {
            "code" : "509581000000105",
            "display" : "Newborn blood spot specimen received"
          },
          {
            "code" : "428299008",
            "display" : "Sickle cell screening declined"
          },
          {
            "code" : "947591000000102",
            "display" : "Sickle cell screening declined, no history of being screened"
          },
          {
            "code" : "947611000000105",
            "display" : "Sickle cell screening declined, screened in UK (as reported by parents) with no evidence of result"
          },
          {
            "code" : "947631000000102",
            "display" : "Sickle cell screening declined, screened outside UK with evidence of result"
          },
          {
            "code" : "947651000000109",
            "display" : "Sickle cell screening declined, screened outside UK with no evidence of result"
          },
          {
            "code" : "384351000000105",
            "display" : "Newborn blood spot screening programme, sickle cell repeat screening with further sample required"
          },
          {
            "code" : "947951000000103",
            "display" : "Sickle cell screening, too young for reliable screening (finding)"
          },
          {
            "code" : "947971000000107",
            "display" : "Sickle cell screening, sample taken too soon after blood transfusion (less than 72 hours) (finding)"
          },
          {
            "code" : "947991000000106",
            "display" : "Sickle cell screening, insufficient sample"
          },
          {
            "code" : "948011000000100",
            "display" : "Sickle cell screening, unsuitable sample (blood quality): incorrect blood application"
          },
          {
            "code" : "948031000000108",
            "display" : "Sickle cell screening, unsuitable sample (blood quality): compressed/damaged"
          },
          {
            "code" : "948071000000105",
            "display" : "Sickle cell screening, unsuitable sample: day 0 and day 5 on same card"
          },
          {
            "code" : "952321000000109",
            "display" : "Sickle cell screening, unsuitable sample: NHS number missing/not accurately"
          },
          {
            "code" : "952341000000102",
            "display" : "Sickle cell screening, unsuitable sample: date of sample missing/not accurately recorded"
          },
          {
            "code" : "952361000000101",
            "display" : "Sickle cell screening, unsuitable sample: date of birth not accurately matched (finding)"
          },
          {
            "code" : "952381000000105",
            "display" : "Sickle cell screening, unsuitable sample: expired card used"
          },
          {
            "code" : "952401000000105",
            "display" : "Sickle cell screening, unsuitable sample: more than 14 days in transit, too old for analysis"
          },
          {
            "code" : "952421000000101",
            "display" : "Sickle cell screening, unsuitable sample: damaged in transit"
          },
          {
            "code" : "952521000000100",
            "display" : "Sickle cell screening, too premature for testing"
          },
          {
            "code" : "427854007",
            "display" : "Sickle cell trait not suspected"
          },
          {
            "code" : "442018007",
            "display" : "Carrier of sickle cell gene mutation"
          },
          {
            "code" : "771461000000105",
            "display" : "Sickle cell trait not suspected, no other haemoglobin or thalassaemia excluded"
          },
          {
            "code" : "931981000000104",
            "display" : "Result consistent with haemoglobin C carrier"
          },
          {
            "code" : "932021000000108",
            "display" : "Result consistent with haemoglobin D carrier"
          },
          {
            "code" : "932061000000100",
            "display" : "Result consistent with haemoglobin E carrier"
          },
          {
            "code" : "932101000000103",
            "display" : "Result consistent with haemoglobin O-Arab carrier"
          },
          {
            "code" : "384381000000104",
            "display" : "Newborn blood spot screening programme, sickle cell not suspected and other disorders follow up required (finding)"
          },
          {
            "code" : "428485006",
            "display" : "Suspected sickle cell trait"
          },
          {
            "code" : "302751000000100",
            "display" : "Newborn blood spot screening programme, sickle cell not screened for or screening incomplete"
          },
          {
            "code" : "948241000000108",
            "display" : "Sickle cell not screened for or screening incomplete, over 1 year old, too old for screening"
          },
          {
            "code" : "948261000000109",
            "display" : "Sickle cell not screened for or screening incomplete, moved out of area"
          },
          {
            "code" : "948281000000100",
            "display" : "Sickle cell not screened for or screening incomplete, not contactable, reasonable efforts made"
          },
          {
            "code" : "948301000000104",
            "display" : "Sickle cell not screened for or screening incomplete, baby died"
          },
          {
            "code" : "948321000000108",
            "display" : "Sickle cell not screened for or screening incomplete, not required, previous valid result"
          },
          {
            "code" : "948351000000103",
            "display" : "Haemoglobin S not suspected (by deoxyribonucleic acid), no other haemoglobin or thalassaemia excluded"
          }
        ]
      }
    ]
  },
  "text" : {
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.